dye penetration test astm

ASTM F1886/F1886M-09(2013) Standard Test Method for Determining Integrity of Seals for Flexible Packaging by Visual Inspection; ASTM F1929-12 Standard Test Method for Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration; ASTM D3045 a standard practice for heat aging of plastics without load. Packages. ISTA testing

ASTM A240-316 Stainless Steel: Design: 200°F | 150 psig | 7,942 lb/in. Lateral Spring Rate 0.625 ” Axial Travel | 803 lb/in. Axial Spring Rate 0.125″ Lateral Offset | 225 psig Test Pressure: Testing: 100% Dye-Penetrant | Air, Soap, & Bubble

The duct assembly shown here is being sent for painting before it is shipped. The assembly was fabricated from A-516 Gr. 70 carbon steel material and designed for 16 psig and full vacuum at 302°F. A 100% dye penetrant test, and spot x-ray test of all pipe circumferential and long seam welds was performed prior to shipment. Read More

The expansion joint is 45½” x 75½”. The unit’s bellows, liner, and angle flanges are 304 stainless steel and the cover is carbon steel. The expansion joint is designed for an operating temperature of 500°F at 15 psig. A 100% dye penetrant examination and air and soap leak test …

They are designed for an operating temperature of 400°F at 150 psig. They are capable of 4.25″ lateral deflection and 1° of angular movement. The expansion joints were 100% dye penetrant tested, the bellows longitudinal seams were 100% X-rayed, and a hydro-test at 250 psig was performed prior to shipment. Read More

The bellows are fabricated from 321 stainless steel with 304 liners, and the flanges are 105N carbon steel. The expansion joints are designed for 212°F at 53 psig. They are capable of 1.37″ compression, 0.59″ axial, and 0.39″ lateral movement. A hydro-test and dye-penetration exam were performed on the units prior to shipment. Read More

ASTM F1886/F1886M-09(2013) Standard Test Method for Determining Integrity of Seals for Flexible Packaging by Visual Inspection; ASTM F1929-12 Standard Test Method for Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration; ASTM D3045 a standard practice for heat aging of plastics without load. Packages. ISTA testing

ASTM A240-316 Stainless Steel: Design: 200°F | 150 psig | 7,942 lb/in. Lateral Spring Rate 0.625 ” Axial Travel | 803 lb/in. Axial Spring Rate 0.125″ Lateral Offset | 225 psig Test Pressure: Testing: 100% Dye-Penetrant | Air, Soap, & Bubble

The expansion joint is 45½” x 75½”. The unit’s bellows, liner, and angle flanges are 304 stainless steel and the cover is carbon steel. The expansion joint is designed for an operating temperature of 500°F at 15 psig. A 100% dye penetrant examination and air and soap leak test …

They are designed for an operating temperature of 400°F at 150 psig. They are capable of 4.25″ lateral deflection and 1° of angular movement. The expansion joints were 100% dye penetrant tested, the bellows longitudinal seams were 100% X-rayed, and a hydro-test at 250 psig was performed prior to shipment. Read More

The bellows are fabricated from 321 stainless steel with 304 liners, and the flanges are 105N carbon steel. The expansion joints are designed for 212°F at 53 psig. They are capable of 1.37″ compression, 0.59″ axial, and 0.39″ lateral movement. A hydro-test and dye-penetration exam were performed on the units prior to shipment. Read More